Eurotrade

NPLU-16 ISO – 4-hole gear pump

ISO 4-hole gear pump with rear and side ports, suitable for small truck-mounted cranes.

Displacement: 16.03 cm³/rev

Max continuous pressure: 280 bar

Ask for information

Description

The NPLU gear pump is a hydraulic pump with an ISO 4-hole mounting flange and an 8x32x36 (ISO 14) splined shaft.

The suction and delivery ports are available in both rear and side positions, to suit different installation layouts.

It is a unidirectional pump with a cast iron body and bronze wear plates, designed for medium-duty applications. It is available in right-hand (clockwise) and left-hand (anticlockwise) versions and is suitable for the hydraulic systems of small truck-mounted cranes.

Main features

  • Cast iron body
  • Bronze wear plates
  • ISO 4-hole mounting flange
  • 8x32x36 (ISO 14) splined shaft
  • Rear and side ports
  • Suction G 3/4, delivery G 1/2 (ISO 228 threads)
  • Right-hand and left-hand rotation versions
  • Minimum speed 300 rpm, maximum continuous 2,200 rpm, maximum intermittent 3,000 rpm

⚠️ Do not use with axial or radial loads on the shaft.

Dati di funzionamento

Model Displacement (cm³/rev) Max continuous pressure P1 (bar) Max intermittent pressure P2 (bar) Max peak pressure P3 (bar)
NPLU-10 10,06 280 310 325
NPLU-12 11,92 280 310 325
NPLU-14 13,8 280 310 325
NPLU-16 16,03 280 310 325

P2: 20 seconds max. P3: 6 seconds max.

Dimensions and codes

Model Left-hand code Right-hand code A (mm) B (mm) C (mm) D (mm) Weight (kg)
NPLU-10 10500340104 10500340113 114 80 98 116 6
NPLU-12 10500340122 10500340131 114 80 98 116 6,2
NPLU-14 10500340140 10500340159 120 74 102 120 6,9
NPLU-16 10500340168 10500340177 123,5 77,5 102 120 7,2

Right-hand code = clockwise rotation, left-hand code = anticlockwise rotation. Choose the version according to the direction of rotation of the PTO.

Operating conditions

  • Fluid: mineral or synthetic oil compatible with NBR, FKM, FPM and nylon seals
  • Optimal operating viscosity: 10 – 100 cSt (max 750 cSt at start-up)
  • Recommended viscosity index: > 100
  • Operating temperature: from -15 °C to +100 °C
  • Filtration: 10 µm above 200 bar, 25 µm below 200 bar
  • Inlet pressure: from -0.3 to 2 bar

Information request

    chevron-downarrow-down